﻿1
00:00:00,001 --> 00:00:03,703
Checking the parts,in switching module errors part1

2
00:00:03,719 --> 00:00:16,687
To test this diode, first, we need to detach one of its bases from the board and perform a  three diodes.

3
00:00:16,720 --> 00:00:22,625
This diode which is in a vertical position,

4
00:00:22,766 --> 00:00:33,627
if positive and negative probes are connected to its top and bottom,

5
00:00:34,499 --> 00:00:45,585
0/4 is displayed and by reversing the probes, it must be Overload.

6
00:00:45,610 --> 00:00:52,460
This does not mean that these diodes are usually like this.

7
00:00:52,485 --> 00:01:02,296
All diodes are similar and do not allow anything to pass from any direction.

8
00:01:02,321 --> 00:01:19,647
It is because of the elements with which they are made parallel or series that these values are displayed. In fact, the correct value is 0/7 that you can see and its opposite is Overload.

9
00:01:20,564 --> 00:01:24,523
It is the same for the next diode.

10
00:01:24,555 --> 00:01:35,890
We can test these two diodes by detaching one of the bases. The top side of these two diodes must be Overload as well.

11
00:01:36,117 --> 00:01:54,700
In the end to eradicate the Main Switching error, if the problem is not with the command, IGBTs and the connections with the pins, then it can be said that the problem is with the diodes.

12
00:01:54,771 --> 00:02:04,677
This error can have several reasons at the same time; for example, maybe the IGBT and diode are both burned out.

13
00:02:04,702 --> 00:02:31,938
In the first step, we replace the IGBT but the error still persists. It is better to test all elements and then turn the device on.

14
00:02:38,821 --> 00:02:49,616
Another solution is to check these rectifier diodes located at the transformer output.

15
00:02:49,851 --> 00:02:59,940
Ten rectifier diodes are located in the output of the transformer on the complete switching side.

16
00:03:00,131 --> 00:03:07,340
It is possible that these diodes are faulty and we are going to test them.

17
00:03:07,452 --> 00:03:20,018
So you can easily determine that which part of the switching is not functioning properly.

18
00:03:20,043 --> 00:03:35,331
Here there is a track and by removing the tin on this track, its connection is severed.

19
00:03:35,499 --> 00:03:50,710
By disconnecting this track, the connection between the input of the transformer which is these IGBTs in the bottom side and the top side of the switching is severed.

20
00:03:50,735 --> 00:03:58,481
Then we connect the switch to see whether the error is gone or not.

21
00:03:58,512 --> 00:04:08,154
If this track is severed, only the bottom side of the switching is active and the top side is completely disconnected.

22
00:04:08,179 --> 00:04:22,886
If you are facing this error again, it is obvious that the problem is not with the top side of the circuit and IGBTs, command and the connections of pins must be tested.

23
00:04:22,911 --> 00:04:26,056
More on the Overcurrent error

24
00:04:26,135 --> 00:04:36,053
First, we connect the electricity while the series lamp is in the track of the input electricity.

25
00:04:36,078 --> 00:04:42,886
It was mentioned that there are some protection diodes in the input and output of the transformer.

26
00:04:42,965 --> 00:04:49,627
We simulated the input of the transformer and our assumption is that the protection diode is burned out.

27
00:04:49,673 --> 00:04:59,996
Then we short-circuit it and by connecting switch number two,

28
00:05:00,074 --> 00:05:21,659
the lamp series which is located in the track of the input electricity stays on and disconnects the system completely.

29
00:05:21,684 --> 00:05:32,700
This is a sign of the Overcurrent error of board number two and we need to find the problem which is the diode that we short-circuited.

30
00:05:46,900 --> 00:05:55,867
You can see that when the switch is connected, the lamp series turns on and disconnects the electricity.

31
00:05:55,892 --> 00:06:08,576
By disconnecting the series lamp in the track of the electricity and by connecting the switch, you can see the Overcurrent error of board number two.

32
00:06:08,601 --> 00:06:21,407
When the device is assembled, there is no lamp series in the electricity track and we see Overcurrent error of boards one and two.

33
00:06:21,432 --> 00:06:36,242
If the device is open and if the lamp series is in the circuit, we can easily find the problem at any stage.
