﻿1
00:00:00,031 --> 00:00:02,999
possible errors in the switching module

2
00:00:03,047 --> 00:00:10,898
Overcurrent error of board one and two is one of the most common errors in the switching module.

3
00:00:10,914 --> 00:00:20,703
After making sure that the command module is healthy, in the switching module, we need to find the problem in accordance with the error that we are having on a side.

4
00:00:20,727 --> 00:00:24,968
As mentioned earlier, the input electricity enters from this section

5
00:00:24,992 --> 00:00:35,484
When switch number two is connected, it is converted to DC by the diode bridge and 300 volts DC enters these two lines.

6
00:00:35,578 --> 00:00:40,132
It enters the IGBT from here.

7
00:00:40,344 --> 00:00:54,664
If you pay careful attention to the complete Main Switching, you can see that these female pin headers are connected to this part.

8
00:00:54,789 --> 00:01:02,593
These connections enter the command module from here.

9
00:01:02,664 --> 00:01:12,695
This means that the command pulses enter this part from here and then go to the IGBTs.

10
00:01:28,002 --> 00:01:36,611
Each of these pins is connected to one of these IGBT pins.

11
00:01:36,636 --> 00:01:43,364
Some of the problems that some users might face are that when the IGBTs are placed on the board,

12
00:01:43,575 --> 00:02:03,215
while installing them in this section, the pads may be detached, or if the tin of these bases is weak, the connection between this IGBT base and the pin header may not be established.

13
00:02:03,247 --> 00:02:11,778
So the first step is to examine the command and after making sure that the command is healthy, we enter the switching module.

14
00:02:11,803 --> 00:02:17,201
First we perform the IGBTs’ test.

15
00:02:17,419 --> 00:02:24,043
We set the multimeter at diode test mode.

16
00:02:24,349 --> 00:02:32,395
The second and third bases from the top for every IGBT are drain and source bases.

17
00:02:32,631 --> 00:02:49,270
We connect the negative and positive probes of the multimeter to the second and third bases, respectively, and the approximate value of 0/4 must be displayed and in the opposite state is Overload.

18
00:02:49,442 --> 00:03:02,325
We perform the test for every one of these IGBTs.

19
00:03:03,387 --> 00:03:11,153
So examining the command is the first step and then we need to test the IGBTs to see if one of them is burned out.

20
00:03:11,177 --> 00:03:24,614
If drain and source has a 0/4 value and its opposite state is open or is not Overload and if gate and source bases are open,

21
00:03:24,661 --> 00:03:34,668
that IGBT is burned out.

22
00:03:34,716 --> 00:03:53,637
So far we know that the IGBTs are healthy.

23
00:03:53,848 --> 00:04:14,715
We set the multi-meter at Buzzer mode and check the connection between these IGBTs and these pin that connect the command and the switching module.

24
00:04:14,740 --> 00:04:27,549
From the top, the gate and source of the first IGBT must be connected to pins number one and two, respectively.

25
00:04:27,667 --> 00:04:34,393
The connection between this pin and here is a track from inside the switching module.

26
00:04:34,421 --> 00:04:44,854
When the IGBT is changed, it is possible that this track is disconnected or it does not have any tin and the connection is not properly established.

27
00:04:44,956 --> 00:04:53,768
Then, the second IGBT and its source are connected to pin number 3 and pin number 4, respectively.

28
00:04:53,800 --> 00:05:45,464
The source of the third IGBT is connected to the last three pins and for the fourth IGBT, the second base which is its gate and its source is connected to the last three pins. If all of the connections are correct, the IGBTs and their connection to the command module are completely healthy.

29
00:06:10,372 --> 00:06:25,783
In the end, we precede one more step and if we still are not able to eradicate the Overcurrent error,

30
00:06:25,862 --> 00:06:33,709
there is one more thing that we can do which will be explained in the following.

31
00:06:33,734 --> 00:06:49,662
There is a set of protection diodes in the input and output of the transformer so that they can neutralize any sudden voltage and also there are two protection diodes in the current output.

32
00:06:49,740 --> 00:07:09,068
We can examine these diodes by a diode test.

33
00:07:23,694 --> 00:07:31,998
This diode that is located at the two ends of this transformer, since it is located at the two ends of a coil and normally,

34
00:07:31,992 --> 00:07:38,168
these two ends are connected to each other,

35
00:07:38,193 --> 00:07:49,279
by testing it we can see that the two ends are connected so the only way to test this diode is to remove one diode base from the circuit and then test it.
