﻿1
00:00:18,941 --> 00:00:21,218
Short-Circuit Impedance Tab

2
00:00:21,243 --> 00:00:27,484
To perform a short-circuit impedance test, as can be seen in the picture, the primary winding is short-circuited.

3
00:00:27,509 --> 00:00:34,109
AC current injection is done through the secondary coil and the voltage difference that happens on the terminals,

4
00:00:34,134 --> 00:00:36,570
is measured through the inputs of the device.

5
00:00:36,602 --> 00:00:40,250
This measurement must be repeated for the other secondary coils.

6
00:00:40,275 --> 00:00:46,181
The obtained impedance called Zsc_x is a combination of primary and secondary stray losses.

7
00:00:46,206 --> 00:00:55,834
Where RP”, Xp” and x stand for the resistance of the primary winding which is transferred to the secondary side,

8
00:00:55,859 --> 00:01:00,271
the leakage reactance of the primary winding which is referred to the secondary side,

9
00:01:00,296 --> 00:01:07,740
and the indicator which is considered for the secondary winding or in other words for where the current is injected from, respectively.

10
00:01:07,765 --> 00:01:10,396
Performing the test and anlyizng the results

11
00:01:10,421 --> 00:01:18,584
To perform this test, first, 1 is entered as the amount of the injected current in I test field and 1 is entered as the test time in State Time.

12
00:01:18,609 --> 00:01:23,967
By pressing Insert Rows button, it is possible to create other rows for testing other coils.

13
00:01:23,992 --> 00:01:28,256
After adjusting these settings, the wiring must be done according to this picture.

14
00:01:28,281 --> 00:01:34,767
In this picture, first phase of current groups A and B are made series so that the maximum Burden of the device is used.

15
00:01:34,800 --> 00:01:38,087
Then, the outputs of the device are connected to the CVT.

16
00:01:38,112 --> 00:01:42,579
To measure the caused voltage difference, input number 1 must be used.

17
00:01:42,604 --> 00:01:50,030
It should be noted that, in this wiring the voltage connectors are connected ahead of the connectors of current injection.

18
00:01:58,338 --> 00:02:05,095
Finally, to perform the test, by right-clicking on any of the rows in Table section and selecting Apply Test,

19
00:02:05,120 --> 00:02:09,806
the test is run and the resistance value of the intended coil is measured.

20
00:02:09,831 --> 00:02:14,938
After the test is finished, to add the results to the report “Add to Report” button can be used.

21
00:02:14,963 --> 00:02:23,813
Also, by using the cog next to this button, you can remove the items they do not wish to be added to the report before selecting “Add to Report” option.

22
00:02:23,838 --> 00:02:29,743
if you, for any reason, wish to modify the wiring of the device, first they need to apply the test

23
00:02:29,768 --> 00:02:36,415
once and then check “Don’t Change Hardware Setting” option and select a different output from “Hardware Configuration”

24
00:02:36,440 --> 00:02:43,891
window and then set the Output Target at “IL1-E” and run the test after changing the wiring.

25
00:02:43,924 --> 00:02:52,509
To select other inputs, it should be noted that the selected Binary Input Target must be in accordance with the default “Binary Input Target”.

26
00:02:52,534 --> 00:03:00,852
For this, it is suggested to right-click on “Input1” row and “Cut” the information and “Paste” it in the intended row.
