﻿1
00:00:26,748 --> 00:00:26,813
V

2
00:00:26,814 --> 00:00:26,878
VI

3
00:00:26,879 --> 00:00:26,944
VI 

4
00:00:26,945 --> 00:00:27,010
VI S

5
00:00:27,011 --> 00:00:27,075
VI St

6
00:00:27,076 --> 00:00:27,141
VI Sta

7
00:00:27,142 --> 00:00:27,206
VI Star

8
00:00:27,207 --> 00:00:27,272
VI Start

9
00:00:27,273 --> 00:00:27,338
VI Starti

10
00:00:27,339 --> 00:00:27,403
VI Startin

11
00:00:27,404 --> 00:00:27,469
VI Starting

12
00:00:27,470 --> 00:00:27,535
VI Starting"

13
00:00:27,536 --> 00:00:27,600
VI Starting" 

14
00:00:27,601 --> 00:00:27,666
VI Starting" R

15
00:00:27,667 --> 00:00:27,732
VI Starting" Ro

16
00:00:27,733 --> 00:00:27,797
VI Starting" Roo

17
00:00:27,798 --> 00:00:27,863
VI Starting" Room

18
00:00:27,864 --> 00:00:27,929
VI Starting" Room 

19
00:00:27,930 --> 00:00:27,994
VI Starting" Room S

20
00:00:27,995 --> 00:00:28,060
VI Starting" Room Se

21
00:00:28,061 --> 00:00:28,126
VI Starting" Room Set

22
00:00:28,127 --> 00:00:28,191
VI Starting" Room Sett

23
00:00:28,192 --> 00:00:28,257
VI Starting" Room Setti

24
00:00:28,258 --> 00:00:28,323
VI Starting" Room Settin

25
00:00:28,324 --> 00:00:28,388
VI Starting" Room Setting

26
00:00:28,389 --> 00:00:28,454
VI Starting" Room Setting:

27
00:00:28,455 --> 00:00:29,055
VI Starting" Room Setting:

28
00:00:29,113 --> 00:00:34,210
To continue with explaining “VI Starting” room, in this video we are going to explain “Setting” tab.

29
00:00:34,235 --> 00:00:36,671
you can adjust some of the test settings.

30
00:00:36,696 --> 00:00:42,320
In this tab, In “Time” section, first, the injection time before fault in “PreFault Time” is entered.

31
00:00:42,345 --> 00:00:51,572
In “Max Fault Time”, the maximum fault injection time is specified in the form of “Abs” or “Rel” which itself includes three sections.

32
00:00:51,597 --> 00:01:01,504
Note that if the time specified in “Max Fault Time” is shorter than time of the “Pick up” time of the shot point, result of the evaluation will be wrong.

33
00:01:01,529 --> 00:01:09,628
If you are using “Max Fault Time (Abs)” field, you need to enter a time in terms of seconds for the maximum fault signal injection time (for all points).

34
00:01:09,652 --> 00:01:14,204
But, to increase the speed of the test, you can use “Max Fault Time (Rel)”.

35
00:01:14,228 --> 00:01:17,533
By checking this option, three other options appear.

36
00:01:17,558 --> 00:01:20,738
By entering a number in “Add%ofTnom”,

37
00:01:20,777 --> 00:01:29,108
the fault signal injection time in each point equals the test point nominal time plus a percentage of the nominal time entered in this field.

38
00:01:29,132 --> 00:01:34,747
This means that if the test point nominal time is 10 seconds and 5 percent is entered in this field,

39
00:01:34,771 --> 00:01:41,221
the maximum fault injection time (105) percent of the test nominal time which is 10.5 seconds.

40
00:01:41,245 --> 00:01:49,187
But in “Add Absolute” field, the fault injection time is entered as a sum of the test point trip nominal time plus the time entered in this field.

41
00:01:49,211 --> 00:01:55,431
For points which are in “No Trip” area, it is possible to enter a separate time in “No-Trip Time” field.

42
00:01:55,455 --> 00:02:00,500
If you enter the time in these 3 fields, the software will consider the longest time.

43
00:02:00,524 --> 00:02:04,122
Post Fault” time is entered in “Post Fault Time”.

44
00:02:04,146 --> 00:02:14,068
“Delay After Trigger” is used for specifying the trigger time of the intended key and by right-clicking on the related field and selecting “Go To Linked Value”,

45
00:02:14,092 --> 00:02:18,415
you can see that it is linked to “CB Trip Time” and if necessary,

46
00:02:18,439 --> 00:02:23,231
by selecting “Remove Link” you can enter your desired value instead.

47
00:02:23,255 --> 00:02:29,055
In “Load Current (PreFault Current)” section, it is possible to adjust the settings related to “PreFault” phase and current.

48
00:02:29,079 --> 00:02:38,525
 By selecting “Based on Current” radio button in “Amplitude” section, the “PreFault” current is entered in ampere which is the same for all other test points.

49
00:02:38,549 --> 00:02:46,302
But, by selecting “Based on IFault”, the “PreFault” current is entered in fault current which is different for every “Shot” point.

50
00:02:46,326 --> 00:02:51,791
You can use “Phase” section for the angle between current and voltage in “PreFault”.

51
00:02:51,815 --> 00:03:01,079
But, by selecting “Same as Fault Angle”, the angle between current and voltage in “PreFault” will be the same with “Fault” which is different for every “Shot” point.

52
00:03:10,001 --> 00:03:14,931
In “Search Setting” section, the settings related to “Search Test” are specified.

53
00:03:14,955 --> 00:03:19,768
As mentioned before, “Search Test” gives a result when one of these conditions are met.

54
00:03:19,793 --> 00:03:31,527
The first condition is “Relative” meaning if the difference between the test point value and previous test point is less than the percentage specified in this field, this point is the response of the test.

55
00:03:31,551 --> 00:03:41,050
The second condition is “Absolute” meaning if the difference between the test point and previous point is less than the value specified in this field, this point is the response of the test.

56
00:03:41,074 --> 00:03:51,012
And the third condition is “Max Point Number” meaning the test cannot be performed more than the number of points entered in this field and the last point is the response of the test.

57
00:03:51,036 --> 00:03:56,789
But, if for any reasons, the nominal characteristic specified for the test is not available,

58
00:03:56,813 --> 00:04:03,212
you can use the “Ignore Nominal Characteristic” section.By doing so, the software ignores the current characteristic.

59
00:04:03,236 --> 00:04:09,127
Then, according to the steps entered in “Search Interval”,shots are added to the “Search” line.

60
00:04:09,151 --> 00:04:12,578
For example, in “Search Test” section, a line is drawn.

61
00:04:12,602 --> 00:04:17,478
Then, 0.5 is entered in “Search Interval” and “Apply to all” is selected.

62
00:04:17,503 --> 00:04:21,729
You can see that points with this step are shot on the “Search” line.

63
00:04:21,753 --> 00:04:31,260
By performing the test, you can see that it starts from the lowest point and when one of the three mentioned conditions are met, the test gives a result.

64
00:04:31,284 --> 00:04:36,372
If necessary, it is possible to disable this option by selecting “Disable all”.

65
00:04:36,396 --> 00:04:44,841
In “Trigger” tab, you can select your intended binary to receive the “Pick up” signal, cutting the injection of current and voltage.

66
00:04:45,405 --> 00:04:51,418
The explanation and settings of this section are the same as those for “Trigger” in “Sequencer” room.

67
00:04:51,545 --> 00:04:56,425
In “Binary Output” tab, if it is necessary for the relay to see the key condition,

68
00:04:56,449 --> 00:05:08,213
by using the “A” or “B” group voltages or “Aux DC” it is possible to take any needed voltage to the “Binary Input” of the relay through “Binary Output” of the device.

69
00:05:08,237 --> 00:05:15,929
This tab has three “PreFault”, Fault” and “Post Fault” modes and you can specify the settings of each one separately.
