﻿1
00:00:26,919 --> 00:00:26,957
T

2
00:00:26,958 --> 00:00:26,996
Tr

3
00:00:26,997 --> 00:00:27,035
Tra

4
00:00:27,036 --> 00:00:27,074
Tran

5
00:00:27,075 --> 00:00:27,113
Trans

6
00:00:27,114 --> 00:00:27,153
Transi

7
00:00:27,154 --> 00:00:27,192
Transie

8
00:00:27,193 --> 00:00:27,231
Transien

9
00:00:27,232 --> 00:00:27,270
Transient

10
00:00:27,271 --> 00:00:27,309
Transient 

11
00:00:27,310 --> 00:00:27,348
Transient A

12
00:00:27,349 --> 00:00:27,387
Transient As

13
00:00:27,388 --> 00:00:27,426
Transient Ass

14
00:00:27,427 --> 00:00:27,465
Transient Asse

15
00:00:27,466 --> 00:00:27,504
Transient Asses

16
00:00:27,505 --> 00:00:27,543
Transient Assess

17
00:00:27,544 --> 00:00:27,582
Transient Assessm

18
00:00:27,583 --> 00:00:27,622
Transient Assessme

19
00:00:27,623 --> 00:00:27,661
Transient Assessmen

20
00:00:27,662 --> 00:00:27,700
Transient Assessment

21
00:00:27,701 --> 00:00:27,739
Transient Assessment"

22
00:00:27,740 --> 00:00:27,778
Transient Assessment" 

23
00:00:27,779 --> 00:00:27,817
Transient Assessment" T

24
00:00:27,818 --> 00:00:27,856
Transient Assessment" Ta

25
00:00:27,857 --> 00:00:27,895
Transient Assessment" Tab

26
00:00:27,896 --> 00:00:28,296
Transient Assessment" Tab

27
00:00:28,321 --> 00:00:33,788
The "Transient Assessment" section is used to assess  the "States"  designed for testing the "Transient".

28
00:00:33,813 --> 00:00:41,282
In this section, a received contact by the device from the relay can be time-compared to the binary signal in the "Comtrade" file.

29
00:00:41,306 --> 00:00:48,055
A sample of the application of this "Assessment" is to compare the performance of the relay while a pplying the signals of

30
00:00:48,095 --> 00:00:55,747
transient condition file so the user would understand whether the relay has a similar function while a default a ccurs.

31
00:00:55,771 --> 00:00:57,595
In the "Measurement View" window,

32
00:00:57,620 --> 00:01:05,235
the "Transient Assessment" tab, a name is be inserted for assessment in the "Name" field so better feedback is obtained from the specified item.

33
00:01:05,259 --> 00:01:08,481
In the "Transient" field, the intended "State" would be selected.

34
00:01:08,505 --> 00:01:14,069
remembar only the name of "States" which are "Transient" type are displayed in this field.

35
00:01:14,093 --> 00:01:21,513
In the "signal" field, a binary signal is selected for comparison with the reference signal from the "Comtrade" signal.

36
00:01:21,537 --> 00:01:29,783
In this field, the list of all the binaries activated in the "Hardware Configuration" are displayed and one of them should be selected.

37
00:01:29,807 --> 00:01:34,776
In the "Reference Signal" field, the reference signal is selected from the "Comtrade" file.

38
00:01:34,800 --> 00:01:41,050
By clicking on this field, all the existing binary signals in the loaded "Comtrade" file are displayed.

39
00:01:41,074 --> 00:01:49,216
 "T Dev. -" field, the negative time tolerance related to the digital signal edge is specified and imported in the "Comtrade" file.

40
00:01:49,240 --> 00:01:57,963
In the "T Dev. +" field, the positive time tolerance related to the digital signal edge is specified and imported in the "Comtrade" file.

41
00:01:57,987 --> 00:02:02,945
The result of the assessment after running the test is displayed in the "Assessment" field.

42
00:02:02,969 --> 00:02:09,094
The green color means the test is "Passed" and the red color meant that the test is "Failed".

43
00:02:09,118 --> 00:02:16,747
In the "User Comment" field, a message can be written about the test, before and after the test which will be used in the output report.

44
00:02:16,771 --> 00:02:24,899
By right-clicking on the "Transient Assessment" the tabs and options are displayed that are similar to right-clicking on the "Time Assessment" tab,

45
00:02:24,923 --> 00:02:28,540
which is alrady explained in the previous educational videos (Time Assessment).

46
00:02:28,564 --> 00:02:33,877
The assessment in this tab is defined according to the comparison of the signal with the reference signal.

47
00:02:33,901 --> 00:02:40,985
For assessment, if both the signals are identical in the specified time period and have a similar status, then the assessment is "Passed".

48
00:02:41,064 --> 00:02:49,487
Otherwise, the assessment is "Failed" showing that the relay didn’t have a similar performance while importing error and had another status.

49
00:02:49,511 --> 00:02:54,575
To do this at first, some adjustments should be performed in some windows.  test is discussed.

50
00:02:54,599 --> 00:02:58,279
 selected in the "Detail View" window and by clicking on the "Import Comtrade…" file,

51
00:02:58,303 --> 00:03:03,352
the transient state of the "Micom p441" relay is loaded.

52
00:03:04,148 --> 00:03:07,792
Then, by clicking on the "Current State" option from the toolbar,

53
00:03:07,816 --> 00:03:15,204
all the active and inactive binaries existing in the "Comtrade" file and the voltage and current signals are displayed.

54
00:03:15,236 --> 00:03:23,904
. then, by checking the "Calculate RMS, Phase and Other", the software calculates the effective values and the phases of the signals.

55
00:03:23,928 --> 00:03:28,004
subsequemtly, from the "Detail View" window and "Binary out" tab,

56
00:03:28,029 --> 00:03:30,708
each of the existing signals in the "Comtrade" file

57
00:03:30,962 --> 00:03:36,686
 tested and assessed should be ascribed to a "Binary Output" and selected as the reference signal.

58
00:03:36,868 --> 00:03:43,946
In this video, two "ZONE1" and "ANY TRIP" signals are ascribed to "binary out" 1 and "Binary Out" 2,

59
00:03:43,970 --> 00:03:50,503
respectively and the reception of trip signal from the relay signal is compared to "ZONE1" signal to be assessed.

60
00:03:50,527 --> 00:03:54,452
In the "Hardware Configuration" window, "Binary / Analog Input" tab,

61
00:03:54,476 --> 00:04:02,238
 binary 1 with the name of "Trip" is connected to the relay trip contact for comparison with the active reference signal.

62
00:04:02,341 --> 00:04:09,056
In the "Transient Assessment" tab, in the "Name" field a name for example "trip1" is inserted for assessment.

63
00:04:09,080 --> 00:04:14,100
The "State1" that is a transient state is selected in the "Transient State".

64
00:04:14,124 --> 00:04:24,817
In the "Reference Signal", the reference signal that is selected in the "Binary Output" is inserted (ZONE1) and the "Trip" signal is selected in the "Signal" field for comparison.

65
00:04:24,841 --> 00:04:30,300
In the "T Dev. -" and "T Dev. +" time tolerance of "3" is inserted.

66
00:04:30,324 --> 00:04:33,560
In order to observe the "Binary Input" status,

67
00:04:33,585 --> 00:04:42,313
the "All State" option are selected from the toolbar and the test is excuted so the error is applied to the relay.

68
00:04:42,913 --> 00:04:48,398
finally, in the "Signal View"  the relay has the same performance as the reference signal,

69
00:04:48,422 --> 00:04:53,022
which is defined as the "Binary Output1", and the assessment result is "Passed".
