﻿1
00:00:23,299 --> 00:00:23,370
C

2
00:00:23,371 --> 00:00:23,442
Co

3
00:00:23,443 --> 00:00:23,515
Con

4
00:00:23,516 --> 00:00:23,587
Cont

5
00:00:23,588 --> 00:00:23,659
Conti

6
00:00:23,660 --> 00:00:23,731
Contin

7
00:00:23,732 --> 00:00:23,803
Continu

8
00:00:23,804 --> 00:00:23,876
Continuo

9
00:00:23,877 --> 00:00:23,948
Continuou

10
00:00:23,949 --> 00:00:24,020
Continuous

11
00:00:24,021 --> 00:00:24,092
Continuous

12
00:00:24,093 --> 00:00:24,164
Continuous R

13
00:00:24,165 --> 00:00:24,237
Continuous Ra

14
00:00:24,238 --> 00:00:24,309
Continuous Ram

15
00:00:24,310 --> 00:00:24,381
Continuous Ramp

16
00:00:24,382 --> 00:00:24,453
Continuous Ramp

17
00:00:24,454 --> 00:00:24,525
Continuous Ramp T

18
00:00:24,526 --> 00:00:24,598
Continuous Ramp Ty

19
00:00:24,599 --> 00:00:24,670
Continuous Ramp Typ

20
00:00:24,671 --> 00:00:24,742
Continuous Ramp Type

21
00:00:24,743 --> 00:00:25,243
Continuous Ramp Type

22
00:00:25,295 --> 00:00:27,945
This “State Type” is similar to “Step Ramp”.

23
00:00:27,970 --> 00:00:35,939
The only difference is that in “Step Ramp” the parameter changes step by step at user-defined time intervals but in “Continuous Ramp”,

24
00:00:35,964 --> 00:00:40,995
the parameters increase or decrease continuously with 400 microseconds time steps.

25
00:00:41,020 --> 00:00:44,889
The parameters adjusted for “Continuous Ramp” include start value,

26
00:00:44,913 --> 00:00:53,703
final value and total time and the start values are specified in “Start Values” table. Here, the values for voltage signals are 5,

27
00:00:53,727 --> 00:00:55,822
10 and 15 volts.

28
00:00:55,854 --> 00:01:03,207
“Binary Output”, “Binary Input” and “Other Setting” sections have been described before and we can skip them.

29
00:01:03,275 --> 00:01:07,826
In “Final Values” table the final value of the parameters is specified.

30
00:01:07,921 --> 00:01:12,663
Here, the values for voltage signals are 20, 25 and 30 volts.

31
00:01:12,912 --> 00:01:18,162
In “Total Time” field in the “Continuous Ramp Setting” section the total time of the “State”

32
00:01:18,178 --> 00:01:23,866
is specified which is linked with the “Timeout” time in “State Termination” in “Trigger” setting.

33
00:01:23,891 --> 00:01:34,682
“Trigger”, “Offset Value”, “Error/Trigger Overcurrent” and “Disable Relay” sections have been described in previous videos and more descriptions should not be necessary here.

34
00:01:34,797 --> 00:01:40,470
Another important matter about “Ramp” is that, in addition to put ramp on voltage and current,

35
00:01:40,589 --> 00:01:45,071
in “Step Ramp” the user can put ramp on impedance by changing the “Set Mode”.

36
00:01:45,086 --> 00:01:51,832
Since the hardware is only capable of recognizing voltage and current and cannot recognize the impedance parameter,

37
00:01:51,857 --> 00:01:58,476
and because there are so many impedance parameters, it is not possible to send these parameters to the hardware in every “Step”.

38
00:01:58,571 --> 00:02:05,041
So, in “Step Ramp” firstly all values of impedance steps are sent to the software and then measured voltage and

39
00:02:05,093 --> 00:02:07,596
current sent to the hardware as an array hardware

40
00:02:07,621 --> 00:02:12,120
every time “Step” in “Continuous Ramp” is 400 microseconds,

41
00:02:12,145 --> 00:02:21,422
the amount of calculations and arrays is greatly increased and it is not possible for the results of the calculations and created arrays to be sent to the hardware.

42
00:02:21,442 --> 00:02:25,312
So, this “State Type” is always carried out in “General: Direct” mode.
