﻿1
00:00:23,101 --> 00:00:23,143
I

2
00:00:23,144 --> 00:00:23,187
In

3
00:00:23,188 --> 00:00:23,230
Int

4
00:00:23,231 --> 00:00:23,273
Intr

5
00:00:23,274 --> 00:00:23,316
Intro

6
00:00:23,317 --> 00:00:23,360
Introd

7
00:00:23,361 --> 00:00:23,403
Introdu

8
00:00:23,404 --> 00:00:23,446
Introduc

9
00:00:23,447 --> 00:00:23,489
Introduct

10
00:00:23,490 --> 00:00:23,533
Introducti

11
00:00:23,534 --> 00:00:23,576
Introductio

12
00:00:23,577 --> 00:00:23,619
Introduction

13
00:00:23,620 --> 00:00:23,662
Introduction 

14
00:00:23,663 --> 00:00:23,706
Introduction t

15
00:00:23,707 --> 00:00:23,749
Introduction to

16
00:00:23,750 --> 00:00:23,792
Introduction to 

17
00:00:23,793 --> 00:00:23,835
Introduction to R

18
00:00:23,836 --> 00:00:23,879
Introduction to Ri

19
00:00:23,880 --> 00:00:23,922
Introduction to Rio

20
00:00:23,923 --> 00:00:24,623
Introduction to Rio

21
00:00:24,648 --> 00:00:29,615
By opening a “Rio” file in notepad, you see that the specifications of the relay are <mentioned> in this file

22
00:00:29,640 --> 00:00:36,643
. For example, between “BEGIN DEVICE” and “END DEVICE” section, information and nominal specifications of the relay are mentioned

23
00:00:36,668 --> 00:00:42,790
Or, in the “BEGIN DEVICE” section to the “END DISTANCE”, the information regarding the distance function and in the

24
00:00:42,815 --> 00:00:46,719
“BEGIN ZONE” section, the information regarding the relay zones are

25
00:00:46,744 --> 00:00:50,270
Similarly, all the relay information is mentioned in this file

26
00:00:50,295 --> 00:00:55,648
By having a “Rio” file, you can “Load” this file in “Test Object” through “File” option

27
00:00:55,673 --> 00:01:00,747
After loading, all of the information existing in the Rio file is displayed

28
00:01:00,772 --> 00:01:06,906
So, the second method for entering information of relays whose software gives a “Rio” output file,

29
00:01:06,931 --> 00:01:09,820
is loading “Rio” file  in “Test Object”

30
00:01:09,845 --> 00:01:13,417
This is how the relay information is loaded in the software

31
00:01:13,442 --> 00:01:17,045
The point is that the information in a “Rio” file is fixed,

32
00:01:17,070 --> 00:01:22,893
meaning that it is not possible to add or delete a new block or parameter in the “Device” block

33
00:01:22,918 --> 00:01:28,807
In fact, “Rio” is a fixed file and much of the "Test Object" design is related to the "Rio" file design

34
00:01:28,832 --> 00:01:35,385
The purpose of "Rio" file is that, for example, each "Distance" relay be end to “Device” and “Distance” blocks

35
00:01:35,410 --> 00:01:40,222
and contain a series of nominal specifications, zones and a series of times

36
00:01:40,247 --> 00:01:46,954
However, it is possible that the “Distance” relay itself contains thousands of parameters and not all of these parameters

37
00:01:46,979 --> 00:01:51,036
exist in the “Rio” file but ultimately the “Rio” output file of the “Distance”

38
00:01:51,061 --> 00:01:55,253
relay contains information mentioned in “Device” and “Distance” blocks

39
00:01:55,278 --> 00:01:59,385
This is, also, true for “Differential” and “Overcurrent” relays

40
00:01:59,410 --> 00:02:06,687
So, the “Rio” file is a fixed part of the relay settings and includes information related to “Device” block and protective functions

41
00:02:06,712 --> 00:02:12,998
Also, the “CB Configuration” block is added to “Rio” files for simulation of power key operation

42
00:02:13,037 --> 00:02:15,982
It is possible to add other blocks to “Rio” file

43
00:02:16,007 --> 00:02:22,085
For example, by opening “AMT Distance” room from “Test Object” window it is possible to add another block,

44
00:02:22,110 --> 00:02:26,041
if necessary, by right-clicking on “Rio” and selecting the “Add Block” option

45
00:02:26,066 --> 00:02:30,817
After making a new block, it is possible to rename it by right-clicking on the block

46
00:02:30,912 --> 00:02:38,732
Assume that a relay has two functions of “Distance” and “Under Excitation”. This functions are tested by impedance method

47
00:02:38,757 --> 00:02:42,444
So it is necessary that there are two “Distance” blocks in this section

48
00:02:42,469 --> 00:02:49,761
After adding a new block, by right-clicking on it and selecting “Rename Block”, its name is changed to “Under Excitation”

49
00:02:49,786 --> 00:02:55,131
By double-clicking on “Under Excitation” block and selecting “Zone Setting” tab on this page,

50
00:02:55,156 --> 00:03:01,286
a “Quad” zone is defined for this block according to the settings described in the previous section

51
00:03:01,311 --> 00:03:03,262
After that, click on “OK”

52
00:03:03,287 --> 00:03:07,127
Now that there are two “Distance” blocks, one of them should be active

53
00:03:07,152 --> 00:03:14,590
If the cube next to the block is colored, it means that it is active; if it white, it means that it is not active.

54
00:03:14,615 --> 00:03:22,201
Now, if you click on “OK”, the information of the active distance block is displayed. Here, the “Mho” characteristic is active

55
00:03:22,226 --> 00:03:26,520
Now, for activating the second distance block it is necessary to right-click

56
00:03:26,545 --> 00:03:31,841
on the intended block in the “Test Object” window and select “Set as Active Function”

57
00:03:31,866 --> 00:03:40,156
By doing this, the intended block is activated and the previous block is deactivated and by clicking on “OK” the characteristics of “Distance”

58
00:03:40,213 --> 00:03:45,506
and “Under Excitation” blocks that are from the “Quad” type are displayed in the “Impedance View”

59
00:03:45,531 --> 00:03:49,447
Also, in the advanced mode, it is possible to mix these two blocks

60
00:03:49,472 --> 00:03:53,515
By right clicking on each block of “Rio” file, it is possible to “Delete” it

61
00:03:53,540 --> 00:03:54,740
Column Description

62
00:03:54,765 --> 00:03:58,180
Each of these parameters has some information in their row

63
00:03:58,205 --> 00:04:04,074
In The “State” column, by double-clicking on each cell, “Rio Parameter Viewer” page is opened

64
00:04:04,099 --> 00:04:11,801
in the “Enabled” section, you can activate or deactivate this parameter. By deactivating a parameter, the status of its “state” changes

65
00:04:11,826 --> 00:04:15,398
In the “Name” column, the name of the intended parameter is provided

66
00:04:15,423 --> 00:04:19,293
In the “ID” column, there is a unique name selected for each parameter

67
00:04:20,714 --> 00:04:26,063
. In the “Description” column, there is an additional description provided for the intended parameter

68
00:04:26,088 --> 00:04:30,481
In the “Value” column, the user can select a value for the intended parameter

69
00:04:30,506 --> 00:04:35,215
In the “Type” column, the type of the inserted data for the parameter is specified.

70
00:04:35,240 --> 00:04:41,165
. In the “Min” and “Max” columns, the minimum and maximum allowed value for the parameter are specified

71
00:04:41,190 --> 00:04:48,539
The “Formula” column is an indicator of that whether this parameter is derived from a formula or is dependent on another parameter

72
00:04:48,564 --> 00:04:51,988
More will be said about this column in the “XRio” section

73
00:04:52,013 --> 00:04:54,212
How to make a Rio file by Excel

74
00:04:54,237 --> 00:04:59,344
The point is that there is a series of relays that do not provide a “Rio” file as an output

75
00:04:59,369 --> 00:05:06,579
To get a “Rio” file from this type of relays, click on the “Excel to Rio Files” icon on the “Rio Converter Excel” page

76
00:05:06,604 --> 00:05:10,332
Then, select your intended relay from the list. In this list,

77
00:05:10,357 --> 00:05:18,233
you can find the name of relays whose “Excel” file exists in the created software. After selecting the relay, its related “Excel” file opens

78
00:05:18,258 --> 00:05:24,865
On this page, you can enter information about the relay and after entering the information, by clicking on the “Save Rio File” option,

79
00:05:24,890 --> 00:05:27,768
a “Rio” file is created from the intended relay

80
00:05:27,793 --> 00:05:34,264
This “Rio” file can be imported by using the “Import from File” icon and after that you can save the relay information

81
00:05:34,289 --> 00:05:37,040
by selecting “Advanced” from the “View” menu,

82
00:05:37,065 --> 00:05:39,812
a new row add to this toolbar page

83
00:05:40,386 --> 00:05:44,786
so you can add or delete new blocks or parameters manually

84
00:05:45,479 --> 00:05:47,079
if you decide to do that.
