﻿1
00:00:24,615 --> 00:00:25,899
Extra Setting

2
00:00:25,924 --> 00:00:29,319
Under the "Extra Setting" tab in the "Hardware Configuration" page,

3
00:00:29,344 --> 00:00:35,008
the settings for the serial port of the device as well as some other operation enhancer settings are set.

4
00:00:35,033 --> 00:00:44,384
In tests where the test run time is longer than 100 seconds, a lot of memory is required to display the "Actual Value" in "Signal View" throughout the test

5
00:00:44,409 --> 00:00:47,407
This amount of information slows down the software.

6
00:00:47,432 --> 00:00:51,529
By checking "Save last actual data" in "Extra Setting" during the test run,

7
00:00:51,554 --> 00:00:58,637
the "Actual Value" is displayed in "Signal View", for example in the last 10 seconds of the test, according to the amount of data.

8
00:00:58,662 --> 00:01:02,777
In fact, this option plays the role of a short memory oscilloscope.

9
00:01:02,802 --> 00:01:06,245
By clicking on "Maximum fan during test" during the test run,

10
00:01:06,270 --> 00:01:12,940
the fan of the device starts working in "Maximum fan" mode and after the test ends, it returns to normal mode.

11
00:01:12,965 --> 00:01:24,538
In “Binary Link Serial” field, it is possible to enter a number between 0 and 255 so that before the test begins, the device sends a command to the equipment test board through “Binary Output”

12
00:01:24,563 --> 00:01:32,241
number four and this board adjusts the appropriate connections for any of the equipment tests in accordance with the received command.

13
00:01:32,265 --> 00:01:35,509
In this section, there is a part named “Serial Setting”.

14
00:01:35,533 --> 00:01:44,062
By adjusting the settings in this section, it is possible to send a serial "Packet" in each "State" via the "AMT105" device.

15
00:01:44,086 --> 00:01:49,174
In the "Baud Rate" field, the transmitting and receiving speed (the speeds must be the same) are adjusted for making the connection.

16
00:01:49,198 --> 00:01:53,796
In "Data" field, the bit number of each data that is sent is specified.

17
00:01:53,820 --> 00:02:00,779
In this section, to identify the end of the original data, one or two bits, which are called "Stop bit", are sent.

18
00:02:00,803 --> 00:02:08,406
The "Parity" field is used to indicate whether the number of 1 bits is odd or even and is also used to identify the error code.

19
00:02:08,430 --> 00:02:13,492
In the "Initial Serial Command" section, you can write a message to identify the data exchange.

20
00:02:13,516 --> 00:02:19,512
After setting under the "Serial" tab in "Detail View", the sent command is written in the "Serial Command" field.

21
00:02:19,536 --> 00:02:25,663
For each "State" of the device, the "AMT105" can send a command for the intended equipment.

22
00:02:25,687 --> 00:02:34,265
In fact, this section can be used in equipment test because there is an interface board between the "AMT105" and the equipment being tested.

23
00:02:34,289 --> 00:02:42,417
By doing this while performing the test, the device sends a "Serial Command" to the board and this board adjusts the settings according to the "Serial Command".

24
00:02:42,441 --> 00:02:47,058
For example, send "abc" to "State1" and "cvf" to "State2".
