﻿1
00:00:24,722 --> 00:00:24,763
B

2
00:00:24,764 --> 00:00:24,805
Bi

3
00:00:24,806 --> 00:00:24,847
Bin

4
00:00:24,848 --> 00:00:24,889
Bina

5
00:00:24,890 --> 00:00:24,931
Binar

6
00:00:24,932 --> 00:00:24,972
Binary

7
00:00:24,973 --> 00:00:25,014
Binary 

8
00:00:25,015 --> 00:00:25,056
Binary O

9
00:00:25,057 --> 00:00:25,098
Binary Ou

10
00:00:25,099 --> 00:00:25,140
Binary Out

11
00:00:25,141 --> 00:00:25,182
Binary Outp

12
00:00:25,183 --> 00:00:25,224
Binary Outpu

13
00:00:25,225 --> 00:00:25,266
Binary Output

14
00:00:25,267 --> 00:00:25,308
Binary Output’

15
00:00:25,309 --> 00:00:25,350
Binary Output’s

16
00:00:25,351 --> 00:00:25,392
Binary Output’s 

17
00:00:25,393 --> 00:00:25,434
Binary Output’s S

18
00:00:25,435 --> 00:00:25,475
Binary Output’s Se

19
00:00:25,476 --> 00:00:25,517
Binary Output’s Set

20
00:00:25,518 --> 00:00:25,559
Binary Output’s Sett

21
00:00:25,560 --> 00:00:25,601
Binary Output’s Setti

22
00:00:25,602 --> 00:00:25,643
Binary Output’s Settin

23
00:00:25,644 --> 00:00:25,685
Binary Output’s Setting

24
00:00:25,686 --> 00:00:26,386
Binary Output’s Setting

25
00:00:26,411 --> 00:00:30,228
Under the “Binary Output” tab in the “Hardware Configuration” window

26
00:00:30,548 --> 00:00:34,781
the settings related to Binary Outputs of the device are set.

27
00:00:34,806 --> 00:00:38,118
“AMT 105” has four Binary Outputs

28
00:00:38,143 --> 00:00:43,383
and on the back of each of them there is a 10amp/240V relay

29
00:00:43,991 --> 00:00:49,657
Activation or deactivation of “Binary Output” is determined in the "Binary Output Target" column

30
00:00:49,710 --> 00:00:54,560
For example, to activate “Binary Output 1”, by clicking on the related field,

31
00:00:54,585 --> 00:00:58,830
it is possible to select a target according to your need from the drop down list

32
00:00:58,890 --> 00:01:08,129
For example, for Open / Close command of power keys, you can select “CB52a” and “CB52b”.

33
00:01:08,721 --> 00:01:13,274
To deactivate this output, select “Not Used” in the same drop down list

34
00:01:13,299 --> 00:01:17,167
By checking the square option above the device’s “Binary Output” numbers,

35
00:01:17,192 --> 00:01:21,618
it is possible to activate or deactivate all 4 binaries at the same time

36
00:01:21,643 --> 00:01:25,621
In the “Binary Output Label” column just like “Binary Input” section,

37
00:01:25,646 --> 00:01:28,887
a “Label” is selected for the activated Binary Outputs.

38
00:01:28,919 --> 00:01:34,604
After setting the related settings, it is necessary to become familiar with the application of Binary Outputs

39
00:01:34,628 --> 00:01:39,972
 In the older versions of the software, the "Binary Output" was opened and closed only once in every "State"

40
00:01:39,996 --> 00:01:46,775
but in new versions of the software, there is a feature added that allows you to change the status of Binary Outputs up to 4 times in a state

41
00:01:46,799 --> 00:01:50,295
The initial status of a “Binary Output” can be changed in several ways

42
00:01:50,319 --> 00:01:53,204
1- In the “Bin. Out” section in the “Table View” window,

43
00:01:53,228 --> 00:01:56,452
it is possible to change the status of a binary to close or open

44
00:01:56,476 --> 00:02:00,822
by clicking on while any changes are, also, displayed in the “Signal View” at the same time

45
00:02:00,846 --> 00:02:04,906
2- Similarly, it is possible to change the status of binaries in the following address:

46
00:02:04,930 --> 00:02:08,735
Detail View>Analog Out>Analog Output Channels>Binary Outputs

47
00:02:08,759 --> 00:02:11,961
The changes are, also, applied in the “Table View” at the same time

48
00:02:11,985 --> 00:02:17,029
In fact, these two sections are linked and every change is applied in both sections at the same time

49
00:02:17,053 --> 00:02:23,088
3- It is, also, possible to change the status of a “Binary Output” from “Binary Output” tab in “Detail View” section

50
00:02:23,112 --> 00:02:29,353
To determine additional start / stop and other options in a state, “Detail View” section should be used

51
00:02:29,377 --> 00:02:34,592
In this section, for every “State”, you can change the status of Binary Outputs up to 4 times

52
00:02:34,616 --> 00:02:39,893
By entering your desired time in "1st Ch.", "2nd Ch.", "3rd Ch." and "4th Ch."

53
00:02:39,917 --> 00:02:44,193
you can specify the time for changing the Binary Output status

54
00:02:44,217 --> 00:02:46,274
For example, in a normal situation,

55
00:02:46,298 --> 00:02:48,395
 "Bin. Out1" is open

56
00:02:48,419 --> 00:02:54,182
If number "1" is entered in "1st Ch." column, it means that after performing the test,

57
00:02:54,207 --> 00:02:57,798
"Bin. Out" is open for 1 second and then it closes

58
00:02:57,822 --> 00:03:00,871
If "2" is entered in "2nd Ch." column,

59
00:03:00,895 --> 00:03:05,804
it means that 2 seconds after closing, the "Binary Output" must open

60
00:03:05,828 --> 00:03:10,357
As All these changes are simultaneously displayed in "Signal View" as well

61
00:03:10,381 --> 00:03:18,376
You can, similarly, determine the change time for the 3rd and 4th states of the "Binary Output" for "3rd Ch." and "4th Ch." columns

62
00:03:18,415 --> 00:03:23,817
In the Trigger column, it is possible to set a condition for executing the changes for “Binary Output”

63
00:03:23,841 --> 00:03:30,738
and no changes are made to the “Binary Output” until the "Trigger" condition is met and the binary remains the same.

64
00:03:30,762 --> 00:03:37,797
After the “Trigger” condition is met, the “Binary Output”, immediately, starts changing its status according to the specified time

65
00:03:37,821 --> 00:03:43,453
 By clicking on the “Toggle” column, a list of other Binary Outputs is opened and by selecting any of them,

66
00:03:43,477 --> 00:03:48,109
the status of the “Binary Output” will be the opposite of the intended binary.

67
00:03:48,133 --> 00:03:53,862
This means that whenever “Binary Out 1” is closed, “Binary Out 3” must be open and vice versa
