﻿1
00:00:24,165 --> 00:00:24,222
A

2
00:00:24,223 --> 00:00:24,279
An

3
00:00:24,280 --> 00:00:24,337
Ana

4
00:00:24,338 --> 00:00:24,395
Anal

5
00:00:24,396 --> 00:00:24,453
Analo

6
00:00:24,454 --> 00:00:24,511
Analog

7
00:00:24,512 --> 00:00:24,569
Analog

8
00:00:24,570 --> 00:00:24,627
Analog O

9
00:00:24,628 --> 00:00:24,685
Analog Ou

10
00:00:24,686 --> 00:00:24,742
Analog Out

11
00:00:24,743 --> 00:00:24,800
Analog Outp

12
00:00:24,801 --> 00:00:24,858
Analog Outpu

13
00:00:24,859 --> 00:00:24,916
Analog Output

14
00:00:24,917 --> 00:00:24,974
Analog Output

15
00:00:24,975 --> 00:00:25,032
Analog Output S

16
00:00:25,033 --> 00:00:25,090
Analog Output Se

17
00:00:25,091 --> 00:00:25,148
Analog Output Set

18
00:00:25,149 --> 00:00:25,205
Analog Output Sett

19
00:00:25,206 --> 00:00:25,263
Analog Output Setti

20
00:00:25,264 --> 00:00:25,321
Analog Output Settin

21
00:00:25,322 --> 00:00:25,379
Analog Output Setting

22
00:00:25,380 --> 00:00:25,980
Analog Output Setting

23
00:00:26,005 --> 00:00:28,588
By clicking on "Hardware Configuration",

24
00:00:28,613 --> 00:00:34,170
a new page with the same name opens where the settings for voltage and current outputs,

25
00:00:34,241 --> 00:00:41,233
, binary inputs and outputs of the device as well as some other settings in "Extra setting" are set

26
00:00:41,306 --> 00:00:48,416
In "Analog output" tab, the settings for voltage and current outputs, activeness or inactiveness of outputs,

27
00:00:48,618 --> 00:00:54,209
labeling them and displaying the actual values for the output signals of the device are adjusted

28
00:00:54,234 --> 00:00:56,486
In "Voltage and Current Output" sections,

29
00:00:56,511 --> 00:01:02,984
the maximum receivable voltage and current from the outputs of the device are specified according to their wiring,

30
00:01:03,009 --> 00:01:06,267
which the users can use depending on their needs

31
00:01:06,292 --> 00:01:08,278
By selecting any of the options,

32
00:01:08,303 --> 00:01:14,427
a figure of the wiring for receiving the required voltage and current is displayed in a box in the middle of the page

33
00:01:14,452 --> 00:01:22,181
For example, by selecting single-phase 300 V, to receive up to 300 V with a 400 mA current,

34
00:01:22,206 --> 00:01:25,471
the user needs to do the wiring according to this figure

35
00:01:25,496 --> 00:01:29,342
In the "Current Output" section, there is some information about wiring

36
00:01:29,367 --> 00:01:33,528
For example, in the first wiring, there are 6 32 amp current Outputs

37
00:01:33,553 --> 00:01:40,875
In this case, a maximum 32 amp with 3 V is injected from every phase and

38
00:01:40,900 --> 00:01:45,970
up to 5 amp with 12 V is receivable from the current outputs

39
00:01:45,995 --> 00:01:51,870
In the "Show Actual Value" column in "Voltage Output Signal” and "Current Output Signal" sections,

40
00:01:51,895 --> 00:01:57,894
it is possible to activate displaying the "Actual" value of output signal in the "Signal View" window

41
00:01:57,919 --> 00:02:05,213
To do this, you need to change the value of the cell of your intended signal in the "Show Actual Value" from "False" to "True"

42
00:02:05,238 --> 00:02:11,271
For example, if the "Show Actual Value" of "VL1-E" signal is changed to "True",

43
00:02:12,333 --> 00:02:15,108
by running the test,

44
00:02:15,133 --> 00:02:19,500
it is observed that there are circles on the waveform of its signal

45
00:02:19,525 --> 00:02:24,790
In the "Output Label" column, it is possible to specify a "Label" for each of the outputs

46
00:02:24,815 --> 00:02:28,167
. In addition to the labels in the drop-down field,

47
00:02:28,192 --> 00:02:31,645
it is possible to add new label by typing it

48
00:02:31,670 --> 00:02:38,115
In the "Output Target" column for each of outputs a target will be specified

49
00:02:38,140 --> 00:02:44,443
In selecting an "Output Target", it is important to note that each of these "Output Target" has a meaning

50
00:02:44,468 --> 00:02:51,271
For example, if "VL1-E" is selected for the first output of the "voltage output A"  and

51
00:02:51,296 --> 00:02:54,877
"IL1" for the first output of the "Current output A",

52
00:02:54,902 --> 00:03:04,591
by selecting "Set Mode: Z-I const", the software divides the 2 volts of "VL1-E" into 1 amp of "IL1" ,

53
00:03:04,616 --> 00:03:11,029
which are the first output of the "voltage output A" and the first output of the "Current output A", respectively,

54
00:03:11,054 --> 00:03:15,264
to simulate phase to ground fault with a 2 ohm fault impedance

55
00:03:15,289 --> 00:03:23,302
Now, if, in the "Hardware Configuration" page, "VL1-E" is selected for the second output of "voltage output A",

56
00:03:23,327 --> 00:03:26,752
in simulating the fault impedance of the previous example,

57
00:03:26,777 --> 00:03:33,530
the software, again, divides the 2 volts voltage of "VL1-E" into 1 amp current of "IL1",

58
00:03:33,555 --> 00:03:40,139
except that this time the voltage of "VL1-E" and "IL1" is injected from the second output of the

59
00:03:40,164 --> 00:03:45,112
"voltage output A" and the first output of the "Current output A", respectively

60
00:03:45,137 --> 00:03:52,199
also It should be noted that if "VL3-E" is selected for the third output of the "voltage output A",

61
00:03:52,224 --> 00:03:58,195
and the same "Output Target" is selected for the single-phase output of the "voltage output B",

62
00:03:58,220 --> 00:04:04,366
the third output of the "voltage output A"  changes to "Not Used" and this "Output Target"

63
00:04:04,391 --> 00:04:08,210
is selected for the single-phase output of the "voltage output B"

64
00:04:08,235 --> 00:04:13,317
This means that each of the available "Output Target" can only be selected for a single output

65
00:04:13,342 --> 00:04:16,377
As another example, in the "AMT Distance" Room,

66
00:04:16,402 --> 00:04:22,654
the software uses "voltage output A" and "Current output A" to simulate fault impedance

67
00:04:22,686 --> 00:04:28,654
If the user wants to use the "Current output B" instead of the "Current output A" for current injection,

68
00:04:28,679 --> 00:04:33,514
they should select "IL1", "IL2" and "IL3" as the "Output Target"

69
00:04:33,539 --> 00:04:38,187
for the three outputs of the "Current output B" in the "Hardware Configuration" page
