﻿1
00:00:25,496 --> 00:00:29,761
By opening each room, a page which contains several windows opens

2
00:00:30,023 --> 00:00:34,352
Along with these windows there is the toolbar and the statusbar

3
00:00:34,722 --> 00:00:41,242
After closing these windows, the explanation of different parts of the menu and the toolbar will be given in the video

4
00:00:41,267 --> 00:00:48,365
This toolbar is the same in all sections and the “Sequencer” room has another toolbar which is exclusive to it

5
00:00:51,015 --> 00:00:55,545
To open a new room, click on "file" and select “new"

6
00:00:57,906 --> 00:01:02,654
You can also access the files that have already been saved by selecting “open"

7
00:01:02,679 --> 00:01:10,145
Use “save" or “save as" to save a file. Use “recent" to access the files that have recently been saved

8
00:01:10,602 --> 00:01:14,507
Use “security” to encrypt a file

9
00:01:14,917 --> 00:01:18,143
The encryption has three levels

10
00:01:18,167 --> 00:01:26,323
The first level ,“full permission”, allows users with an encryption code to access the settings, run the test file and save the output

11
00:01:27,950 --> 00:01:34,406
In the second level, users cannot change the settings but can only run the test file and save the output

12
00:01:35,135 --> 00:01:39,062
in the third level of encryption, users can only view the file.

13
00:01:40,156 --> 00:01:44,189
Use "export report" to save the test file as PDF

14
00:01:44,720 --> 00:01:48,835
Use “exit" to close and exit the test page

15
00:01:49,501 --> 00:01:54,996
Click on “view" and select “toolbars" to see different modes of the toolbar

16
00:01:55,266 --> 00:01:58,759
 remove the check mark to show or hide the icons

17
00:01:58,783 --> 00:02:03,961
Use “status bar" to hide or show the status bar at the bottom of the page

18
00:02:03,985 --> 00:02:06,317
The "units" option has three parts:

19
00:02:06,341 --> 00:02:09,011
1- Choosing  time between “cycles" and “seconds”

20
00:02:09,035 --> 00:02:15,742
By default, time is displayed in terms of seconds while by selecting ”cycles” the time is displayed in terms of cycles

21
00:02:15,766 --> 00:02:21,809
Determine the cycle time in “test object", the “device” block and then in the “f nom” field

22
00:02:21,833 --> 00:02:26,190
If this frequency is changed the time is change accordingly

23
00:02:26,214 --> 00:02:30,426
2- Choosing Parameter’s values between “Absolute” and “Relative”

24
00:02:30,450 --> 00:02:37,279
By default Parameters' values are “Absolute”. use “Relative” to see parameters' values dependent to nominal value

25
00:02:37,303 --> 00:02:44,047
The nominal values for voltage can be determined in the “test object”, “device” and in the “V nom (secondary)” field,

26
00:02:44,078 --> 00:02:49,276
for current in the “I nom(secondary)” and for frequency in the (f nom) field

27
00:02:49,759 --> 00:02:53,266
3- Choosing values between “Primary” and “Secondary

28
00:02:53,829 --> 00:03:00,755
By default, software values are in terms of “secondary”. to see the values in terms of “primary” use the “primary” option

29
00:03:02,294 --> 00:03:09,672
These values can be determined in the “test object”, “Device” block, “V primary” and “I primary” field

30
00:03:10,187 --> 00:03:17,099
The “communication logger" option is for the communications of devices and laptops that the Vebko’s programmers use.

31
00:03:17,123 --> 00:03:22,959
different windows in the “sequencer” page including “vector view" and “signal view” are shown in this list

32
00:03:23,125 --> 00:03:30,200
use "Revision History" to access all of the files that were saved by the program every 30 seconds

33
00:03:31,303 --> 00:03:35,192
by selecting each file you can reset them as needed

34
00:03:35,620 --> 00:03:40,312
Select “start/continue" option in the “test" menu to run the test

35
00:03:40,336 --> 00:03:43,217
to stop the test use “stop”

36
00:03:43,463 --> 00:03:47,208
use “clear" to remove the test results

37
00:03:47,826 --> 00:03:53,599
In the “parameter” menu select “test object” to open “General test object” page

38
00:03:54,035 --> 00:03:57,835
Select “Report” to open “report setting” page

39
00:04:00,938 --> 00:04:08,859
Use “Delete all added reports" to remove all of the reports that have been added to the output report using the “add to report” option

40
00:04:08,883 --> 00:04:11,854
Using "Number of Decimal Places Setting" option,

41
00:04:11,878 --> 00:04:17,474
depended page opens and you can determine parameter units and Determine how to display numbers

42
00:04:17,498 --> 00:04:24,733
If an error occurs during the test, in the “hardware" menu click on “clear error" to remove it and run the test again

43
00:04:26,876 --> 00:04:31,875
Use “reset hardware” to reset the device’s hardware automatically.

44
00:04:31,899 --> 00:04:39,540
Select “configuration” to open the “hardware configuration" page. In this page output voltage and current
45
00:04:39,817 --> 00:04:44,756
input and output binaries setting and extra setting is set.

46
00:04:45,526 --> 00:04:48,490
Click on "Calibration" to open the calibration page

47
00:04:48,514 --> 00:04:52,697
This page is used for device calibration by vebko’s experts.

48
00:04:53,967 --> 00:04:57,741
In the "Window" menu you can adjust the layouts.

49
00:04:57,765 --> 00:05:03,800
The “System Default Layout” option displays a default arrangement of windows for the software.

50
00:05:04,093 --> 00:05:10,345
also The "Custom Default Layout" option displays the windows as "Default Layout" saved by the user.

51
00:05:10,369 --> 00:05:17,134
The "Default Undock" option displays the windows as "Undock" and the location of each window can be adjusted.

52
00:05:17,634 --> 00:05:22,078
With the "Cascade" option, the windows are in a row and behind each other

53
00:05:22,609 --> 00:05:28,105
Note that these options are used when the room "Layout" is in “Default undock Mode”.

54
00:05:28,645 --> 00:05:36,075
The "Default Layout for transient" option is for the test mode and the "Default for Quick" option is used for the "Quick" mode.

55
00:05:36,177 --> 00:05:43,146
"Manage Layout...” is used to store the desired layouts, and even several "Layout" can be stored in it .

56
00:05:43,607 --> 00:05:50,456
To use a stored "Layout" click on its name, then select “Apply Layout" to open the "Layout“.

57
00:05:51,082 --> 00:05:58,649
By choosing the "Current Style as default" option, the page layout that is being used is determined a "Custom Default Layout"

58
00:05:58,673 --> 00:06:06,918
The "schema” option shows different states and colors for the toolbar and the background of the test page which can be selected as desired.

59
00:06:06,949 --> 00:06:12,626
In the "Help" menu, the "Help topics" option opens the tips of the software and the tester.

60
00:06:13,102 --> 00:06:17,762
The "Shortcut keys" option shows all the shortcut keys in the software.

61
00:06:17,786 --> 00:06:22,130
The "About" option also gives the user information about the company.
