﻿1
00:00:24,266 --> 00:00:25,946
General Setting of Rooms

2
00:00:26,075 --> 00:00:29,348
There are four main tabs in the software “setting” page.

3
00:00:29,373 --> 00:00:32,847
The “Room” tab provides a number of features for different rooms.

4
00:00:33,316 --> 00:00:39,614
In the "Date-Time" section, you can select “Persian” or “Christian” as the type of the date used in the output report.

5
00:00:39,726 --> 00:00:46,947
By using the other three options in this section, it is possible to show the name of the month and week and milliseconds in the report.

6
00:00:46,971 --> 00:00:55,758
In rooms such as "AMT-Distance" and "AMT-Overcurrent", next to each of the "Fault Types" are written numbers which show the test points,

7
00:00:55,791 --> 00:00:59,681
the number of passed test points, the number of failed test points,

8
00:00:59,729 --> 00:01:06,362
the number of test points that are outside the range of the device and the number of untested test points respectively.

9
00:01:06,473 --> 00:01:07,725
With this explanation,

10
00:01:07,733 --> 00:01:16,024
unchecking each of these options in the "Show/Hide Test Counters" will cause the number of points associated with that option not to be displayed.

11
00:01:16,048 --> 00:01:22,865
In the "Report Refresh Interval" field of the "Report" section, the update time for the report is specified.

12
00:01:22,897 --> 00:01:27,244
In the "Report Package" section, the default settings for the "Reports" are adjusted.

13
00:01:27,308 --> 00:01:36,982
In the "Extra Tools" section, clicking on the " Template  Report Generator", opens the "PDF Report Creator" page where the desired test files can be imported to get a report.

14
00:01:37,149 --> 00:01:46,944
By clicking on "Remove Signature", the "Remove Signature from Report" page opens where, without needing to open the test files, the added signatures to the reports can be removed.

15
00:01:46,976 --> 00:01:55,035
In the "Template" section, the settings of the "Test Object" of the device as well as the settings related to displaying numbers in the "Decimal Places" are adjusted.

16
00:01:55,075 --> 00:02:03,075
By checking the "Auto Save" option, the software saves the last changes made to the test page according to the time specified in the "Interval" field.

17
00:02:03,172 --> 00:02:08,861
These files are also saved in the location specified in the “Directory” box in “History” section.

18
00:02:08,923 --> 00:02:18,208
The maximum reserved size for these files and the maximum duration of time that these files are kept in the system is specified in the “Max Size” and “Max Time” filed,

19
00:02:18,233 --> 00:02:21,730
respectively,and the user is able to change these values.

20
00:02:21,755 --> 00:02:25,688
By unchecking any of these options, the limitation is removed as well.

21
00:02:25,847 --> 00:02:32,295
By doing this, if the software crashes for any reason, the test page and the user information will remain safe.

22
00:02:32,320 --> 00:02:41,033
In the "Alert-Tone on Hardware Error" dropdown field, you can select an alert sound for when there is a hardware error in the device.

23
00:02:41,137 --> 00:02:49,694
The settings for specifying and changing the sizes of the tables of the rooms such as "Distance" and "Differential" are adjusted in the "Styles of Tables" section.

24
00:02:49,774 --> 00:02:57,375
You can customize the "Key Setting" section to be able to use the "Enter" key and the arrow keys to move in the cells of a table.

25
00:02:57,510 --> 00:03:06,750
In the "Communication Mode" section, you can choose between "Service System" and "Integrated System" for the connection between different rooms and pages of the software.

26
00:03:06,774 --> 00:03:12,479
"Appearance Setting of Groupbox" is designed for personalizing user interface.

27
00:03:12,545 --> 00:03:21,878
This setting is divided to two categories of “text” and “border”, which are used to personalizing the borders , color and text’s fonts.

28
00:03:22,045 --> 00:03:28,622
In the following tutorials, all of the above will be stated in detail as well as how to adjust the settings.
